Dillon GTX Plus Force Gauge Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Sensores Dillon GTX Plus Force Gauge. Dillon GTX Plus Force Gauge User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
GTX-Plus Series User’s Manual
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1

GTX-Plus Series User’s Manual

Página 2 - Table of Contents

GTX-Plus Series User’s Manual REV 2.1 10 Computer Control of Force Gauge A computer can control the force gauge by sending USB commands. USB Com

Página 3 - Introduction

GTX-Plus Series User’s Manual REV 2.1 11 1.1) AUTO-OFF An Auto-off feature can be enabled to conserve battery power where the gauge powers down a

Página 4 - Battery Indicator

GTX-Plus Series User’s Manual REV 2.1 12 example LOWER LEVEL = 0 N, UPPER LEVEL = 20 N Load The “UPPER” LED will ON. Another LED O

Página 5 - Using the GTX

GTX-Plus Series User’s Manual REV 2.1 13 example LOWER LEVEL = 10 N, UPPER LEVEL = 20 N Load The “UPPER” LED will ON. Another LED OFF.

Página 6 - Basic Functions

GTX-Plus Series User’s Manual REV 2.1 14 To set DROP LEVEL, Press UP and DOWN to move the cursor point to DROP LEVEL and press ENTER key The display

Página 7

GTX-Plus Series User’s Manual REV 2.1 15 1.4) FILTERING This function selects the display throughput rate i.e. the amount of averaging performed by

Página 8

GTX-Plus Series User’s Manual REV 2.1 16 To set the constant factor, Use LEFT ARROW key to move the cursor point to FACTOR constant. Use UP and DOW

Página 9

GTX-Plus Series User’s Manual REV 2.1 17 display will show Start, Stop option menu page. Press ESC key to return the auto averaging menu page. STAR

Página 10 - Main Menu

GTX-Plus Series User’s Manual REV 2.1 18 Use LEFT ARROW keys to move cursor point to the desired value. Use UP and DOWN keys to change the value, pre

Página 11

GTX-Plus Series User’s Manual REV 2.1 19 2) DATABASE This use to view the saved record, delete last record, delete all record and calculate the stat

Página 12 - Lower level

GTX-Plus Series User’s Manual REV 2.1 2 Table of Contents Table of Contents………………………………………………………… 2 Introduction………………………………………………………………… 3

Página 13

GTX-Plus Series User’s Manual REV 2.1 20 Figure 15a Delete last Menu Press UP and DOWN to select NO and YES, If you selected NO and press E

Página 14

GTX-Plus Series User’s Manual REV 2.1 21 SELECT RECORD SAVED RECORD: 002/200 MAX RECORD COUNT: 20 BEGIN RECORD: 001 END RECORD:

Página 15

GTX-Plus Series User’s Manual REV 2.1 22 Figure 16 Date&Time Menu Press UP and DOWN to change the value, press and hold to scroll values.

Página 16

GTX-Plus Series User’s Manual REV 2.1 23 6) ABOUT This shows the information of your gauge (Firmware revision, Model, Capacity, Serial number). To

Página 17

GTX-Plus Series User’s Manual REV 2.1 24 GTX Specifications Capacity and Divisions Model No: mN N kN g-f kg-f oz-f lb-f GTX 5 5000 x 1 5 x 0.001

Página 18

GTX-Plus Series User’s Manual REV 2.1 25 Conversion Factor Unit mN N kN g-f kg-f oz-f lb-f mN 1 0.001 1e-6 101.97e-3 101.97e-6 3.597e-3 2

Página 19

GTX-Plus Series User’s Manual REV 2.1 26 Dillon, a Weigh-Tronix Brand 1000 Armstrong drive Fairmont, Minnesota 56031 Sales (507) 238-8796

Página 20

GTX-Plus Series User’s Manual REV 2.1 3 Introduction Thank you for choosing the Nextech GTX series instrument. With correct use and regular re-cali

Página 21 - SELECT RECORD

GTX-Plus Series User’s Manual REV 2.1 4 Powering the GTX for the first time The GTX is supplied with a set of 4 Nickel Metal Hydride AAA recharg

Página 22

GTX-Plus Series User’s Manual REV 2.1 5 Using the GTX Fitting Accessories Couple fittings directly to the load cell stem or use an extension rod.

Página 23 - Measurement practice

GTX-Plus Series User’s Manual REV 2.1 6 After the self test, providing no load has been applied to the instrument, the display will show all zeroes

Página 24 - GTX Specifications

GTX-Plus Series User’s Manual REV 2.1 7 For tensile force the indicator bar move from right to left. For compressive forces the indicator bar move fr

Página 25

GTX-Plus Series User’s Manual REV 2.1 8 Peak Tension symbol Figure 3b Peak Tension Peak-Compression mode Press MODES key until appeared o

Página 26

GTX-Plus Series User’s Manual REV 2.1 9 Invert Display The display may be inverted or “reversed”, so that the operator can read it more comfortabl

Comentários a estes Manuais